Original Article
 / 
Accuracy of lymphocyte counts from UniCel DxH 800 in β-thalassemia/HbE patients having various numbers of nucleated red blood cells

July 24, 2019

Accuracy of lymphocyte counts from UniCel DxH 800 in β-thalassemia/HbE patients having various numbers of nucleated red blood cells

Sunil Timilsena,1,3 Sakkarin Ardsiri,2 Surada Lerdwana,3 Krishna Das Manandhar,1 Kovit Pattanapanyasat,3 Egarit Noulsri4

1 Central Department of Biotechnology, Tribhuvan University, Kathmandu, Nepal
2 Department of Pediatrics, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
3 Department of Research and Development, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
4 Research Division, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand

Abstract

Background: The UniCel® DxH-800 is an automated cell counter widely used in laboratories. However, the effects of increased nucleated red blood cells (NRBCs) on the lymphocyte counts obtained using the UniCel DxH-800 have not been fully elucidated.
Objective: The study’s objective was to compare lymphocyte counts obtained using the DxH-800 and those obtained using flow cytometry in various ranges of NRBCs.
Methods: This cross-sectional study analyzed 25 healthy volunteers and 69 β-thalassemia/HbE patients. The numbers of lymphocytes were determined using a UniCel DxH-800 and a standard flow cytometer using counting beads.
Results: In healthy volunteers, regression analysis of the lymphocyte counts using the two approaches showed an r2 0.85 and a p < 0.0001, and a Bland-Altman plot showed mean bias of +264 cells/μL. In β-thalassemia/HbE patients, regression analysis of the lymphocyte counts obtained using an automated cell counter and a flow cytometer showed an r2 of 0.06, a p = 0.028, and a Bland-Altman plot showed the mean bias of +1,509 cells/μL. In addition, a high degree of discrepancy in the lymphocyte counts was observed in β-thalassemia/HbE patients who had NRBCs > 100,001 cells/μL.
Conclusions: The present study demonstrated that the UniCel DxH-800 performed well in enumerating lymphocytes in specimens that contained various numbers of NRBCs. However, a high number of NRBCs may interfere with lymphocyte counts obtained using the counter.
Key words: automated cell counter, nucleated red blood cell, lymphocyte, flow cytometry, β-thalassemia,

Full Text
automated cell counter, flow cytometry, lymphocyte, nucleated red blood cell, β-thalassemia

Categories

  • Announcement (1)
  • Case Report (23)
  • Early Online (93)
  • Original Article (223)
  • Review Article (29)

Key words

allergen Allergic rhinitis Allergy Anaphylaxis Asthma atopic dermatitis child Children Chlorhexidine chronic rhinosinusitis chronic spontaneous urticaria Chronic Urticaria COVID-19 cytokine depression diagnosis drug allergy Drug hypersensitivity efficacy Epidemiology food allergy Food hypersensitivity house dust mite IgE Immunotherapy obstructive sleep apnea Omalizumab prevalence primary immunodeficiency Quality of life Questionnaire Reliability risk factor risk factors safety SARS-CoV-2 Sensitization Severe asthma Skin prick test Specific IgE Thai treatment urticaria vaccine Vitamin D
Asian Pacific Journal of Allergy and Immunology

Support Contact

Managing Editor
Ms. Patrawadee Pitakpolrat
E-mail: managingeditor@apjai-journal.org

Production Editor
Ms. Chanita Jangsawang
E-mail: chanita.j@apjai-journal.org

Asian Pacific Journal of Allergy and Immunology © 2025 All rights reserved.
All rights reserved | Privacy Policy